ΑΠΟΛΥΜ/ΚΟ ΕΡΓΑΛ. CIDEX OPA 3,8L

Απολυμαντικο ΕργαλειωνCidex OPA 4L

Κωδικός: 10830-04-0027
Τιμή πώλησης: 76,88 €
62,00 €
ΦΠΑ: 24 % Φ.Π.Α


Διαθεσιμότητα: 1-7 ΗΜΕΡΕΣ

CIDEX® OPA Solution is a high level


disinfectant for reprocessing heat sensitive reusable semi-critical


medical devices, for which sterilization is not feasible, and when


used according to the Directions for Use. CIDEX OPA Solution


is intended for use in manual (bucket and tray) systems made


from polypropylene, acrylonitrile-butadiene-styrene (ABS),


polyethylene, glass-filled polypropylene and/or polycarbonate


plastics. CIDEX OPA Solution may also be used in automated


endoscope reprocessors according to the manufacturer’s


instructions and should be monitored with CIDEX OPA Solution


Test Strips. See DIRECTIONS FOR USE – Reusage for Disinfection.


The semi-critical medical devices reprocessed in CIDEX OPA


Solution must first be cleaned according to a validated cleaning


protocol or standard, such as the ASTM F 1518 “US Standard


Practice for Cleaning and Disinfection of Flexible Fiberoptic and


Video Endoscopes Used in the Examination of the Hollow Viscera.”


Indications for Use: CIDEX OPA Solution is a high level


disinfectant for reprocessing heat sensitive semi-critical medical


devices, for which sterilization is not suitable, and when used


according to the Directions for Use.


Manual Processing: High Level Disinfectant at a minimum


of 20?C (68?F). CIDEX OPA Solution is a high level


disinfectant when used or reused, according to the


Directions for Use, at or above its Minimum Effective


Concentration (MEC) as determined by CIDEX OPA Solution


Test Strips, with an immersion time of at least 12 minutes for


a reuse period not to exceed 14 days.


Automatic Endoscope Reprocessors that can be set to


a minimum of 25?C: High Level Disinfectant at a minimum


of 25?C (77?F). CIDEX OPA Solution is a high level


disinfectant when used or reused in a legally marketed


automatic endoscope reprocessor (that can be set to a


minimum of 25?C) according to the Directions for Use, at or


above its Minimum Effective Concentration (MEC) as


determined by CIDEX OPA Solution Test Strips, with an


immersion time of at least 5 minutes for a reuse period not


to exceed 14 days.


Note: If your AER cannot be set to a minimum of 25?C


please follow the time and temperature stated in Indications


for Use, Manual Processing.


Minimum Effective Concentration (MEC): 0.3%.


Microbicidal Activity: The following table indicates the


spectrum of activity as demonstrated by testing of CIDEX


OPA Solution using prescribed test methods.


MICROORGANISM


VEGETATIVE ORGANISMS


Staphylococcus aureus


Salmonella choleraesuis


Pseudomonas aeruginosa


Mycobacterium bovis


FUNGI


Trichophyton mentagrophytes


VIRUSES


NON-ENVELOPED


Poliovirus Type 1


Rhinovirus Type 42


Adenovirus Type 2


Vaccinia (Wyeth)


Coxsackievirus Type B-3


ENVELOPED


Coronavirus


Cytomegalovirus


Influenza Virus [Hong Kong]


HIV-1


Herpes simplex Types 1,2


To qualify CIDEX OPA Solution as a high level disinfectant,


the reused solution passed the AOAC Sporicidal Activity


Test in 32 hours at 20?C and in 32 hours at 25?C.


Material Compatibility: CIDEX OPA Solution has been tested


and found to be compatible with the materials shown below.


METALS1 PLASTICS5


Aluminum Polymethylmethacrylate (Acrylic)


Anodized aluminum2 Nylon


Brass Polyethylene terephthalate


Carbon steel (Polyester)


Chrome plated brass2 Polystyrene


Chrome plated steel2 Polyvinylchloride (PVC)6


Copper Acrylonitrile/butadiene/styrene (ABS)


Nickel plated brass2 Polysulfone


Nickel silver alloy2 Polycarbonate7


Stainless steel3 Polyethylene


Titanium Polypropylene


Tungsten carbide2 Acetal


Vanadium steel4 PTFE


Polyamide